Duke Energy Florida generate your own

Their own published program, read and recorded. This outranks the Florida state rule wherever the two differ, because it is the program this utility actually administers.

Check an address on this utility free
How the size is measured

gross power rating: the total manufacturer AC nameplate generating capacity of the renewable generation system. For inverter based systems the AC nameplate generating capacity is calculated by multiplying the total installed DC nameplate generating capacity by 0.85 to account for losses during the conversion from DC to AC. The inverter own rating does not determine the tier, so sizing to the Tier 1 boundary means a DC ceiling of 11.764 kW.

Size bands and what each one obliges

Tier 1 Size 0 to 10 kW

No application fee. Insurance of not less than $100,000 is recommended but not required.

  • Standard interconnection agreement
Tier 2 Size 10.001 to 100 kW

A $240 application fee applies, the lowest Tier 2 fee among the Florida investor owned utilities, and insurance of not less than $1,000,000 is required with proof of continuing coverage annually.

  • $240 application fee
  • $1,000,000 liability insurance, proven annually
Tier 3 Size 100.001 to 2000 kW

A $750 application fee applies and insurance of not less than $2,000,000 is required annually. A system impact analysis adds up to 30 business days.

  • $750 application fee
  • $2,000,000 liability insurance, proven annually
  • System impact analysis

The screens that decide it

Ask the utility this, before you sell it

  1. What is the transformer or service drop rating at this address? Duke inspects primarily to check that the system rating does not exceed 90 percent of it, and the applicant pays for any upgrade.
  2. Duke publishes no percentage of annual consumption test. Confirm whether one will be applied to this application.
  3. Duke publishes nothing on battery storage in its tier pages. If a battery is included, confirm what Duke requires.

Worth knowing before you quote

Duke publishes no consumption percentage, no storage rules and no aggregate program cap. Timelines are published per tier: Tier 1 meter replacement within three weeks of a completed application and permission to operate usually within 10 business days of completing requirements; Tier 2 roughly three to four weeks total; Tier 3 adds up to 30 business days of system impact analysis. No customer may operate generation in parallel without prior written consent. As of 31 December 2024 Duke reported 89,710 interconnections totaling 856,734 kW AC.

Source

Duke Energy Florida Tier 1, Tier 2 and Tier 3 generate your own customer pages, with the 2024 Rule 25-6.065(10) report to the Florida Public Service Commission

Read and recorded 2026-09-12. Investor owned utility under Florida Public Service Commission jurisdiction. Duke does not publish its own gross power rating definition and points to the Florida Administrative Code, and its annual report tabulates each interconnection in kW AC, so the rule definition governs.

All Florida interconnection rules

What to do with this

Check a real address

The rules below are the general case. Run the free check to see which utility serves a specific address, which tier the system lands in, and what to ask.

Run the free check
Installers: keep the answer with the job

GridProjeX holds the project from here, with every value tied to the document it came from and the utility and permit tracks run to permission to operate.

How it works for installers
Utilities: see what applicants are told

The same published rules your applicants read here are the ones your queue sees. GridProjeX is the record both sides work from.

How it works for utilities

Also from CivyxIQ, if they fit what you already do: SolarProjeX for running the crews and the jobs, and Solar Home so the homeowner can follow their own project. Neither is needed to use the checker.